Purpose
Vertebral compression fractures (VCFs) of the thoracolumbar spine predominantly result from osteoporosis but may also arise due to trauma, infection, or neoplastic conditions [1]. In Europe, the prevalence of VCF among individuals over 50 years of age is 18–26% [2], while in the United States, 1–1.5 million cases occur annually [3]. These fractures represent the most common osteoporotic injuries after hip fractures [4]. VCFs are categorized according to Genant’s classification based on vertebral height loss (VHL) as: normal (0-20%, grade 0), mild (20–25%, grade 1),...
Methods and materials
CT images were retrospectively and consecutively collected from a large U.S. teleradiology network in April 2023. These scans were obtained for diverse clinical indications unrelated to VCFs. The dataset included images acquired using 34 different scanner models from five manufacturers, ensuring a diverse representation of imaging systems. Inclusion criteria encompassed both non-enhanced and contrast-enhanced CT scans of the chest or abdomen, with either axial or sagittal acquisition views. Scans with slice thickness greater than 3 mm were excluded, as were those of patients younger than...
Results
Of the 319 patients initially screened for inclusion, 100 patients met the criteria, comprising 1,025 vertebrae. The mean patient age was 69 years old ±9.7 [SD] and 67% were female. According to the GT, 20% of cases were positive for VCF and 2.9% of vertebrae exhibited VHL≥ 25%.For vertebral labeling, the algorithm achieved 95.0% overall agreement with the GT (95% CI: 93.5%–96.2%). Discrepancies were mainly caused by L5 lumbar sacralization or vertebrae with severely limited visibility due to high compression (VHL>70%). For VHL quantification, the...
Conclusion
The automated AI software evaluated in this study demonstrated significant potential to enhance the early detection of osteoporosis through vertebral labeling, VHL assessment and fracture detection. By leveraging routine CT scans for opportunistic osteoporosis screening, the software offers cost-effective and low-radiation alternatives to dual-energy X-ray absorptiometry (DXA).The algorithm achieved 95.0% accuracy in vertebral labeling, aligning with state-of-the-art software (84.62%–97.5%) [12–17]. Its VHL measurements matched the GT with 0.18% mean absolute error. Finally, the software achieved 92.3% sensitivity and 91.7% specificity for VCF detection, which are...
Personal information and conflict of interest
C. Castineira:
Employee: Avicenna.AI, La Ciotat, France
J. Sung:
Nothing to disclose
J. Kiewsky:
Employee: Avicenna.AI, La Ciotat, France
Y. Chaibi:
Employee: Avicenna.AI, La Ciotat, France
C. Avare:
Employee: Avicenna.AI, La Ciotat, France
S. Quenet:
Employee: Avicenna.AI, La Ciotat, France
A. Ayobi:
Employee: Avicenna.AI, La Ciotat, France
References
[1] D. Alexandru, W. So, Evaluation and Management of Vertebral Compression Fractures, Perm. J. 16 (2012) 46–51. https://doi.org/10.7812/TPP/12-037.[2] M.T. Löffler, A. Jacob, A. Scharr, N. Sollmann, E. Burian, M. El Husseini, A. Sekuboyina, G. Tetteh, C. Zimmer, J. Gempt, T. Baum, J.S. Kirschke, Automatic opportunistic osteoporosis screening in routine CT: improved prediction of patients with prevalent vertebral fractures compared to DXA, Eur. Radiol. 31 (2021) 6069–6077. https://doi.org/10.1007/s00330-020-07655-2.[3] C. Donnally, C. DiPompeo, M. Varacallo, Vertebral Compression Fractures, in: StatPearls Internet, Treasure Island (FL): StatPearls Publishing, 2023....