2023 ASM / C-12
Artefacts in magnetic resonance imaging of the spine: a review
Type:
Educational Exhibit
Keywords:
MR physics, Musculoskeletal spine, Musculoskeletal system, MR, Diagnostic procedure, Education, Physics, Artifacts
Authors:
M. Mangi, W. Lim
DOI:
10.26044/ranzcr2023/C-12
References
- Krupa K, Bekiesińska-Figatowska M. Artifacts in magnetic resonance imaging. Pol J Radiol. 2015;80:93-106.
- Taber KH, Herrick RC, Weathers SW, Kumar AJ, Schomer DF, Hayman LA. Pitfalls and artifacts encountered in clinical MR imaging of the spine. Radiographics. 1998;18(6):1499-521.
- Singh DR, Chin MSM, Peh WCG. Artifacts in Musculoskeletal MR Imaging. Semin Musculoskelet Radiol. 2014;18(01):012-22.
- Indiran V, Sivakumar V. Diagnostically useful MRI artifact – India ink artifact. Neurology India. 2019;67(2):573-4.
- Peh WC, Chan JH. Artifacts in musculoskeletal magnetic resonance imaging: identification and correction. Skeletal Radiol. 2001;30(4):179-91.
- Larsen DW, Teitelbaum GP, Norman D. Cerebrospinal fluid flow artifact. A possible pitfall on fast-spin-echo MR imaging of the spine simulating intradural pathology. Clin Imaging. 1996;20(2):140-2.
- Delfaut EM, Beltran J, Johnson G, Rousseau J, Marchandise X, Cotten A. Fat suppression in MR imaging: techniques and pitfalls. Radiographics. 1999;19(2):373-82.
- Tehranzadeh J, Andrews C, Wong E. Lumbar spine imaging. Normal variants, imaging pitfalls, and artifacts. Radiol Clin North Am. 2000;38(6):1207-53, v-vi.
- Peterman SB, Hoffman JC, Jr., Malko JA. Magnetic resonance artifact in the postoperative cervical spine. A potential pitfall. Spine (Phila Pa 1976). 1991;16(7):721-5.
- Levitt M, Benjamin V, Kricheff, II. Potential misinterpretation of cervical spondylosis with cord compression caused by metallic artifacts in magnetic resonance imaging of the postoperative spine. Neurosurgery. 1990;27(1):126-9; discussion 9-30.
- Schenck JF. The role of magnetic susceptibility in magnetic resonance imaging: MRI magnetic compatibility of the first and second kinds. Med Phys. 1996;23(6):815-50.
- Rupp R, Ebraheim NA, Savolaine ER, Jackson WT. Magnetic resonance imaging evaluation of the spine with metal implants. General safety and superior imaging with titanium. Spine (Phila Pa 1976). 1993;18(3):379-85.
- Mirowitz SA. Pitfalls, Variants, and Artifacts in Body MR Imaging. St Louis: Mosby-Year Book; 1996.
- Huang SY, Seethamraju RT, Patel P, Hahn PF, Kirsch JE, Guimaraes AR. Body MR Imaging: Artifacts, k-Space, and Solutions. RadioGraphics. 2015;35(5):1439-60.