Results

Consistency in Liver Volumes

In Fig. 4, we can see the volumes (in ml) obtained for the two setups. The liver volumes for the studies are consistent over the two setups with a maximum variation of 2.3% and an average variation of 0.9%.

 

 

Duration of Segmentation : Manual vs Automated

In Fig. 3, we can see the time taken (in mins) for performing liver volumetry on the two setups. Automation of liver volumetry accelerated the post processing significantly. Automated Liver volumetry on PredibleLiver takes an average of 3.5 minutes compared to 14.6 minutes on Commercial CT Volume Viewer.

 

 