[1] Grosswendt B: Backscatter factors for x-rays generated at voltages between 10 and 100 keV,
Physics in Medical and Biology 29(5),
579-591,
1984.
[2] Klevenhagen SC: Experimentally determined backscatter factors for x-rays generated at voltages between 16 and 140 kV,
Physics in Medical and Biology 34(12),
1871-1882,
1989.
[3] Grosswendt B: Dependences of the photon backscatter factor for water on source-to-phantom distance and irradiation field size,
Physics in Medical and Biology 35(9),
1233-1245,
1990.
[4] Jursinic PA: Characterization of optically stimulated luminescent dosimeters,
OSLDs,
for clinical dosimetric measurements,
Medical Physics 34(12),
4594-4604,
2007.
[5] Reft CS: The energy dependence and dose response of a commercial optically stimulated luminescent detector for kilovoltage photon,
megavoltage photon,
and electron,
proton,
and carbon beams,
Medical Physics 36(5),
1690-1699,
2009.
[6] Lehmann J,
Dunn L,
Lye JE et al.: Angular dependence of the response of the nanoDot OSLD system for measurements at depth in clinical megavoltage beams.
Medial Physics 41(6),
061712-1-9,
2014.
[7] Kerns JR,
Kry SF,
Sahoo N et al.: Angular dependence of the nanoDot OSL dosimeter,
Medical Physics 38(7),
3955-3962,
2011.
[8] Al-Senan RM and Hatab MR: Characteristics of an OSLD in the diagnostic energy range,
Medical Physics 38(7),
4396-4405,
2011.
[9] Hayashi H,
Nakagawa K,
Okino H,
Takegami K,
Okazaki T,
Kobayashi I.
High accuracy measurements by consecutive readings of OSL dosimeter.
Medical Imaging and Information Sciences.
2014;31(2):28-34.
[10] Nakagawa K,
Hayashi H,
Okino H,
Takegami K,
Okazaki T,
Kobayashi I.
Fabrication of Annealing Equipment for Optically Stimulated Luminescence (OSL) Dosimeter.
Japanese Journal of Radiological Technology.
2014;70(10):1135-1142 (in Japanese).
[11] Hayashi H,
Takegami K,
Okino H,
Nakagawa K,
Okazaki T,
Kobayashi I.
Procedure to measure angular dependences of personal dosimeters by means of diagnostic X-ray equipment.
Medical Imaging and Information Sciences.
32(1),
8-14,
2015.
[12] Okazaki T,
Hayashi H,
Takegami K,
Okino H,
Nakagawa K.
Evaluation of angular dependence of nanoDot OSL dosimeters toward direct measurement of entrance skin dose.
European Congress of Radiology (EPOS).
2015; DOI: 10.1594/ecr2015/C-0721.
[13] Takegami K,
Hayashi H,
Okino H,
Kimoto N,
Maehata I,
Kanazawa Y,
Tohru O,
Kobayashi I.
Practical calibration curve of small-type optically stimulated luminescence (OSL) dosimeter for evaluation of entrance-skin dose in the diagnostic X-ray.
Radiological Physics and Technology.
2015.
[14] Takegami K,
Hayashi H,
Nakagawa K,
Okino H,
Okazaki T,
Kobayashi I.
Measurement method of an exposed dose using the nanoDot dosimeter.
European Congress of Radiology (EPOS).
2015; DOI:10.1594/ecr2015/C-0218.
[15] H.
Hirayama et al.
The EGS5 Code System.
SLAC Report number: SLAC-R-730.
KEK Report number: 2005-8.,
2013.
[16] EGS5 community HP in KEK,
http://rcwww.kek.jp/egsconf/
[17] L.
Pages,
E.
Bertel,
H.
Joffre,
et al.,
Energy Loss,
Range,
and Bremsstrahlung Yield for 10-kev to 100MeV Electrons in Various Elements and Chemical Compounds,
Atomic Data and Nuclear Data Tables 4,
1-127.
1972.
[18] T.
E.
Johnson,
B.
K.
Birky,
Health Physics and Radiological Health,
Lippincott Williams & Wilkins,
2012.
[19] R.
Beherens,
M.
Kowatari and O.
Hupe.
Secondary Charged Equilibrium in 137Cs and 60Co Reference Radiation Fields.
Radiation Protection Dosimetry,
Vol.
136,
168-175,
2009.